BH9005 Volatile Phenol Water Quality Online Automatic Monitor

 

Product Overview
Phenols can be distilled with water vapor, divided into volatile phenol and non - volatile phenol. Volatile phenol refers to the boiling point below 23ºC of phenols, usually a monophenol. Phenols mainly come from wastewater from oil refining, gas washing, coking, paper making, synthetic ammonia, wood anticorrosion and chemical industry.
Phenols are highly toxic substances, which can denature protein in low concentration and precipitate protein in high concentration. They have direct damage to various cells and strong corrosion effect on skin and mucosa. Drinking water contaminated with phenol for a long time can cause dizziness, rash, pruritus, anemia, nausea, vomiting and various neurological symptoms. Phenolic compounds promote cancer in humans and mammals. National standard gb5749-2006 the content of volatile phenols (including phenol) in drinking water was less than 0.002 mg/L.
The analyzer can be set long-term unattended automatic continuous work according to the site, widely used in industrial pollution sources discharge wastewater, industrial process wastewater, industrial sewage treatment plant sewage, municipal sewage treatment plant sewage and other occasions. According to the complexity of the field test conditions, the corresponding pretreatment system can be selected to ensure the reliability of the test process and the accuracy of the test results, so as to fully meet the site requirements of different occasions.

Product Principle
When the concentration of volatile phenol in the water sample was lower than 0.5mg/L, 4-aminoantipyrine extraction spectrophotometry was used; when the concentration was higher than 0.5mg/L, 4-aminoantipyrine direct spectrophotometry was used. The measurement results were automatically calculated by the input data processing system of the measurement signal. It is mainly used in online monitoring of water quality of rivers, lakes, surface water and groundwater, and water quality of waterworks.

Technical Parameters

No. Name Technical Parameters
1 Application
 
It is widely used in surface water such as industrial sewage, domestic sewage, rivers and lakes and water produced in industrial process.
2 Test Methods 4- aminoantipyrine photometry
3 Measurement range 0~30mg/L
4 Detection lower limit 0.1
5 Resolution 0.01
6 Accuracy Less than ±5%or ±3%F.S
7 Repeatability Less than ±3%or ±2%F.S
8 Zero Drift ±0.5mg/L
9 Span Drift ±10%
10 Measurement cycle The minimum test cycle is 20min. According to the actual water sample, the digestion time can be set from 5 to 120min
11 Sampling period Time interval (adjustable), integral hour or trigger measurement mode can be set.
12 Calibration Automatic calibration (1-99 days adjustable), according to actual water samples, manual calibration can be set.
13 Maintenance Maintenance interval is more than one month, about 30 minutes each time.
14 Operation Touch screen display and instruction input.
15
Self checking protection
Working status is self-diagnostic, abnormal or power failure will not lose data. Automatically eliminates residual reactants and resumes work after abnormal reset or power failure.
16 Data storage No less than half a year data storage
17 Input interface Switch quantity
18 Output interface Two RS232 digital output, One 4-20mA analog output
19 Working Conditions Working indoors; temperature 5-28ºC; relative humidity≤90% (no condensation,no dew)
20 Power Supply &Consumption
AC230±10%V, 50~60Hz, 5A
21 Dimensions Height1500×Width 550×Depth 450(mm)