BH9007 Cyanide Water Quality Online Automatic Monitor/Analyzer

Product Overview:

Cyanide usually refers to the inorganic substance containing cyanide. Common cyanides are sodium cyanide, potassium cyanide and hydrogen cyanide. These simple cyanides are soluble in water and are highly toxic.
Cyanide is very easily absorbed by human body. It can enter the human body through the mouth, respiratory tract or skin. Cyanide enters the stomach and is absorbed immediately by hydrolysis of gastric acid to cyanhydric acid. When this substance enters the blood circulation, the cytochrome oxidase Fe3+ in the blood binds to cyanide, and forms the cytochrome oxidase of iron cyanide, which loses the ability to transmit electrons, interrupts the respiratory chain and causes the cell to asphyxiate and die. Because cyanide is more soluble in lipids, the central nervous system is the first to be harmed, especially the respiratory center. Respiratory failure is the main cause of death from acute cyanide poisoning.
 

Product Principle:

Cyanide on-line automatic analyzer uses water with tartaric acid and zinc nitrate to be heated and distilled.Simple cyanide and some complex cyanide in water sample are distilled in the form of hydrogen cyanide. After absorption with sodium hydroxide, hydrogen chloride is formed with cyanamide T. The reaction of isonicotinic acid and pyrazolone to produce red intermediate product. Red intermediate product is formed rapidly at 546 nm wavelength. It has maximum absorption and is stable for a certain period of time.             
This product is a single factor parameter testing and analysis instrument.

 

Technical Parameters:

No. Name Technical Specifications
1 Application Range This product is suitable for cyanide wastewater in the range of 0~1mg/L.
2 Test Methods Isonicotinic acid-barbituric acid Spectrophotometric method
3 Measuring range 0~1mg/L
4 Detection Lower limit 0.05
5 Resolution 0.001
6 Accuracy ±10% or ±0.1mg/L(Take the bigger value)
7 Repeatability 10% or 0.1mg/L(Take the bigger value)
8 Zero Drift ±0.05
9 Span Drift 10%
10 Measurement cycle Minimum 20 minutes.
11 Sampling period Time interval (adjustable), integral hour or trigger measurement mode can be set.
12 Calibration cycle Automatic calibration (1-99 days adjustable), according to actual water samples, manual calibration can be set.
13 Maintenance cycle Maintenance interval is more than one month, about 30 minutes each time.
14 Human-machine operation Touch screen display and instruction input.
15
Self checking protection
Working status is self-diagnostic, abnormal or power failure will not lose data. Automatically eliminates residual reactants and resumes work after abnormal reset or power failure.
16 Data storage No less than half a year data storage
17 Input interface Switch quantity
18 Output interface Two RS232 digital output, One 4-20mA analog output
19 Working Conditions Working indoors; temperature 5-28ºC; relative humidity≤90% (no condensation,no dew)
20 Power Supply and Consumption
AC230±10%V, 50~60Hz, 5A
21 Dimensions Height1500×Width 550×Depth 450(mm)