FLDUV254 5-beams With Wiper COD Sensor
- Product Name: FLDUV254 5-beams With Wiper COD Sensor
- Product brand:FLUIDINGS
The Fluidings UV254 sensor is an optical-based absorption and transmittance with UV LED and PD technology sensor. The sensor measures the absorption at UV 254 nm, blue, green, red and IR Simultaneously to compensate the SAC measurement for interferences from turbidity and color.
Product brand:FLUIDINGS
The Fluidings UV254 sensor is an optical-based absorption and transmittance with UV LED and PD technology sensor. The sensor measures the absorption at UV 254nm, blue, green, red and IR Simultaneously to compensate the SAC measurement for interferences from turbidity and color.
Features ofFLDUV254 5-beams With Wiper COD Sensor
- 5 wavelength absorption measurement: UV, Vis and IR
- For Turbidity and color compensation.
- SAC measurement used to determine organic loading
without reagents. - Measurement directly in the process, no sample processing
or reagent required. - Fast response, minimum 10 second.
- Cold light source (UV LED) and rugged PD, long life time and
low drift. - Support leakage alarm
- Build in auto wiper sub-system prevents biofouling from
taking place.
Measurement Method | Absorption measurement at 254 nm, DIN 38402 C2, DIN 38404, HJ/T191 standard |
Range | 6mm cuvette gap 0.15~300mg/L equiv. KHP(COD solution) 2mm cuvette gap 0.5~1000mg/L equiv. KHP(COD solution) 2mm cuvette gap 1.5~1500mg/L equiv. KHP(COD solution) |
Resolution | 0.1mg/L or 0.01mg/L COD |
Repeatability | ±1% FS equiv. KHP |
Operating temperature | 0~45℃ |
Storage Temperature | -10~50℃ |
Clean system | Auto wiper system(default) |
Warranty | 1 year |
Depth | IP68, 10m Max |
Power | 12V 20mA (normal), 200mA (Max) |
Output | RS485 and Modbus protocol |
Materials | Titanium, SS316, POM, Nylon, PUR, quartz glass |
Dimensions | Length 280mm, diameter 142x157mm |
Flow rate | < 3 m/s |
Response time | Minimum 10s T90 |
Field life* | Sensor 3 years or greater, wiper sub-system 1.5 years or greater |
Recommended Calibration maintain Frequency* | Sensor 3 months, wiper sub-system inspection 6 months. |
- 5 wavelength absorption measurement: UV, Vis and IR
- for turbidity and color compensation.
- SAC measurement used to determine organic loading
without reagents. - Measurement directly in the process, no sample processing
or reagent required. - Fast response, minimum 10 second.
- Cold light source (UV LED) and rugged PD, long life time and
low drift. - Support leakage alarm
- Build in auto wiper sub-system prevents biofouling from
taking place.
Measurement Method | Absorption measurement at 254 nm, DIN 38402 C2, DIN 38404, HJ/T191 standard |
Range | 6mm cuvette gap 0.15~300mg/L equiv. KHP(COD solution) 2mm cuvette gap 0.5~1000mg/L equiv. KHP(COD solution) 2mm cuvette gap 1.5~1500mg/L equiv. KHP(COD solution) |
Resolution | 0.1mg/L or 0.01mg/L COD |
Repeatability | ±1% FS equiv. KHP |
Operating temperature | 0~45℃ |
Storage Temperature | -10~50℃ |
Clean system | Auto wiper system(default) |
Warranty | 1 year |
Depth | IP68, 10m Max |
Power | 12V 20mA (normal), 200mA (Max) |
Output | RS485 and Modbus protocol |
Materials | Titanium, SS316, POM, Nylon, PUR, quartz glass |
Dimensions | Length 280mm, diameter 142x157mm |
Flow rate | < 3 m/s |
Response time | Minimum 10s T90 |
Field life* | Sensor 3 years or greater, wiper sub-system 1.5 years or greater |
Recommended Calibration maintain Frequency* | Sensor 3 months, wiper sub-system inspection 6 months. |